The HemoCue WBC DIFF System measures white blood cell in order to rapidly provide information about the state of the immune system to medical professionals.
The HemoCue WBC DIFF System measures white blood cell (WBC) count including a five-part differential at the point of care in order to rapidly provide information about the state of the immune system to medical professionals.
Market Suggested Retail Price
$2,000.00
Target Users (Target Impact Group)
Distributors / Implementing Organizations
Distributed by manufacturer
Manufacturing/Building Method
Waiting for response from manufacturer
Intellectural Property Type
Patent Protected
User Provision Model
A WBC DIFF can be purchased from contacting HemoCue on their website. Additional websites, such as Wilburn Medical, also carry the device.
Distributions to Date Status
Unknown
Design Specifications
Technical Support
Provided by manufacturer
Replacement Components
Replacement consumables can be purchased from contacting HemoCue on their website. Additional websites, such as Wilburn Medical, also carry the replacement consumables.
Lifecycle
5 - 10 years
Manufacturer Specified Performance Parameters
The manufacturer specifies a detection range of 300-30000 cells/µL, with a sample volume of 10uL, and a measurement time of less than 5 minutes. Source: WBC Diff Product Sheet
Vetted Performance Status
In the independent study by Hammersmith Hospital, the device provided reliable comparability in the range of 0.4–30.0 × 109/l. This is slightly narrower than the range of 0.3–35 × 109/l specified by the manufacturer; however, samples with WBC < 0.4 × 109/l were flagged as low (code LLL) and conversely, those with counts above 30.0 × 109/l were flagged as high (code HHH); thus, in a clinical setting, this flagging would provide adequately reliable information.
Safety
Unreliably measuring immune function could provide incorrect information to doctors, leading to incorrect diagnosis and treatment.
Complementary Technical Systems
None
Academic Research and References
Osei-Bimpong, A., Jury, C., McLean, R., Lewis, S.M. “Point-of-care method for total white cell count: an evaluation of the HemoCue WBC device.” Int. J. Lab Hematol, 31:6 (2009)
Casey, Janet R., and Michael E. Pichichero. 2009. “A Comparison of 2 White Blood Cell Count Devices to Aid Judicious Antibiotic Prescribing.” Clinical Pediatrics 48 (3): 291–94.
Russcher, H., N. Van Deursen, and R. de Jonge. 2013. “Evaluation of the HemoCue WBC DIFF System for Point-of-Care Counting of Total and Differential White Cells in Pediatric Samples.” Ned Tijdschr Klin Chem.
Lindberg, Stellan, Inger Jönsson, Magnus Nilsson, Elin Johnsson, and Tomas Jonasson-Bjäräng. 2014. “A Novel Technology for 5-Part Differentiation of Leukocytes Point-of-Care.” Point of Care 13 (2).
Compliance with regulations
None
Other Information
None
Agriculture
November 9, 2023
Agriculture
November 9, 2023
Agriculture
November 9, 2023
Agriculture
November 9, 2023
Agriculture
November 9, 2023
Implemented by
Medentech Ltd
Agriculture
November 9, 2023
Agriculture
November 9, 2023
Agriculture
November 9, 2023
Implemented by
Allspeeds
Agriculture
November 9, 2023
Agriculture
November 9, 2023
Have thoughts on how we can improve?
Give Us Feedback
The main material is polyethylene, which is cheap, but has a short lifetime. It is only the fittings that are of PVC. A 40 m3 system provides enough gas to run a small engine for a few hours a day to generate electrcity, as long as there is sufficient feed material, usually cattle dung. The performance figures seem reasonable.
Not available yet?
Jeremy Schonhorn says:
A few more references
Hemocue References
Casey, Janet R., and Michael E. Pichichero. 2009. “A Comparison of 2 White Blood Cell Count Devices to Aid Judicious Antibiotic Prescribing.†Clinical Pediatrics 48 (3): 291–94.
Russcher, H., N. Van Deursen, and R. de Jonge. 2013. “Evaluation of the HemoCue WBC DIFF System for Point-of-Care Counting of Total and Differential White Cells in Pediatric Samples.†Ned Tijdschr Klin Chem. nvkc.nl. https://www.nvkc.nl/sites/d….
Lindberg, Stellan, Inger Jönsson, Magnus Nilsson, Elin Johnsson, and Tomas Jonasson-Bjäräng. 2014. “A Novel Technology for 5-Part Differentiation of Leukocytes Point-of-Care.†Point of Care 13 (2). journals.lww.com: 27.
Jeremy Schonhorn says:
The Hemocue WBC Diff system is a vetted technology to determine white blood cell count (neutrophils, lymphocytes, monocytes, eosinophils and basophils). Although the device is powered with batteries, they are increasingly accessible in remote locations and should not be considered a limitation to usability and portability.
The technology is accessible and ability to profile blood at the point of care from finger stick whole blood will enable physicians and health care providers to assess patient health (e.g. trauma, infection).
Two fields in the performance parameter table for this kind of products: “ICT technology platform” is not appropriate (Maximum current and Maximum power)
The firmware that Angaza provides should be in terms of quality of service. Two suggestion would be additional cost to products, bandwidth requirement and training/technical support.
Checking the ICT only field, the performance parameters make more sense for Angaza and Lumeter: User coverage, service needed, etc.